The building coverage ratio (建蔽率) caps how much of a site a building may cover when seen from directly above. The floor area ratio (容積率) caps the total floor area of a building relative to the site. Both are set by the Building Standards Act, and a building must satisfy both at once. In the Takken exam's land-use restrictions they appear as calculation problems and as questions on whether a relaxation applies.
This guide follows the Building Standards Act (Arts. 52, 53, 53-2 and 54) and its Enforcement Order as in force on November 27, 2026. The e-Gov revision history shows no enacted amendment changing these articles by April 1, 2027. An amendment due on July 30, 2028 only updates the name and item number of a statute cited in Art. 52 and does not change the limits.
Key takeaways
- Building coverage ratio = building area ÷ site area; floor area ratio = total floor area ÷ site area. Both divide by the site area; the numerators differ.
- For building coverage, the Act gives a set of options for each use district and the city plan selects one. The commercial district is fixed at 8/10 (80%).
- For floor area ratio, the upper limit is the smaller of the designated ratio and the front-road limit (when the road is under 12 m wide): the road width in meters multiplied by 4/10 or 6/10. When there are two or more front roads, use the widest.
- When a site straddles several districts, both ratios are limited to the average weighted by the area in each district.
- Building coverage relaxations add 10 percentage points for fire-resistant buildings and similar in fire prevention districts and quasi-fire prevention districts, and 10 for corner lots, 20 if both apply. In a fire prevention district whose designated coverage is 80%, a fire-resistant building and similar is not subject to the coverage limit at all.
Designated building coverage and floor area ratios
Options for building coverage and floor area ratio by use district
| District | Building coverage (Art. 53(1)) | Floor area ratio (Art. 52(1)) |
|---|---|---|
| Category I and II exclusive low-rise residential districts, and agricultural residential district | The city plan selects 3/10, 4/10, 5/10 or 6/10 | Selects from 5/10, 6/10, 8/10, 10/10, 15/10, 20/10 |
| Category I and II exclusive mid/high-rise residential districts | Same (3/10 to 6/10) | Selects from 10/10, 15/10, 20/10, 30/10, 40/10, 50/10 |
| Category I and II residential districts, quasi-residential district | Selects from 5/10, 6/10, 8/10 | Same (10/10 to 50/10) |
| Quasi-industrial district | Selects from 5/10, 6/10, 8/10 | Same (10/10 to 50/10) |
| Neighborhood commercial district | Selects from 6/10, 8/10 | Same (10/10 to 50/10) |
| Commercial district | 8/10 (fixed) | Selects from 20/10 to 130/10 in steps of 10/10 |
| Industrial district | Selects from 5/10, 6/10 | Selects from 10/10, 15/10, 20/10, 30/10, 40/10 |
| Exclusive industrial district | Selects from 3/10, 4/10, 5/10, 6/10 | Same (10/10 to 40/10) |
| Area with no use district designated | The Specified Administrative Agency sets one of 3/10 to 7/10 (3, 4, 5, 6, 7) | The Agency sets one of 5/10, 8/10, 10/10, 20/10, 30/10, 40/10 |
In the exam you are normally given the designated ratios, and the skill tested is deciding which adjustments apply. Use the table above to check that a given value is a possible option for that district.
How the areas are measured
- Site area: the horizontal projection of the site. The strip between a line deemed to be the road boundary under Art. 42(2) (a setback) and the actual road is not counted (Order Art. 2(1)(i)).
- Building area: the horizontal projection of the part enclosed by the center lines of the outer walls or columns. If eaves, canopies and similar parts project 1 m or more horizontally from the center line, measure to a line 1 m back from their tips (Order Art. 2(1)(ii)).
- Total floor area: the sum of the floor areas of all floors. For floor area ratio, certain parts are excluded from it (Order Art. 2(1)(iv); Act Art. 52(3) and (6)).
Building coverage: relaxations and adjustments
Adjustments to the building coverage limit (Art. 53)
| Situation | Result | Article |
|---|---|---|
| Fire-resistant building and similar in a fire prevention district (except where the designated ratio is 80%), or fire-resistant or quasi-fire-resistant building and similar in a quasi-fire prevention district | +10 points | Art. 53(3)(i) |
| Site at a street corner or similar, designated by the Specified Administrative Agency | +10 points | Art. 53(3)(ii) |
| Both of the above | +20 points | Art. 53(3) |
| Fire-resistant building and similar in a fire prevention district whose designated ratio is 80% | The coverage limit does not apply (100% is allowed) | Art. 53(6)(i) |
| Site straddles the boundary of a fire prevention district and all buildings on it are fire-resistant and similar | The whole site is treated as inside the fire prevention district | Art. 53(7) |
| Site straddles two or more districts or areas | At most the sum of each district's limit multiplied by the share of the site in that district | Art. 53(2) |
| The Specified Administrative Agency grants permission (buildings within a wall line, work on exterior walls for energy-saving improvement, and similar) | The limit may be exceeded within the scope of the permission | Art. 53(4), (5) |
How the floor area ratio limit is set
The floor area ratio limit is the smaller of (1) the ratio designated in the city plan and (2) when the front road is under 12 m wide, the figure below (Art. 52(1) and (2)).
Front-road limit on floor area ratio
| Use district | Figure multiplied by road width (general rule) | Note |
|---|---|---|
| Category I and II exclusive low-rise residential districts, agricultural residential district | 4/10 | None |
| Category I and II exclusive mid/high-rise residential districts, Category I and II residential districts, quasi-residential district | 4/10 | 6/10 in areas designated by the Specified Administrative Agency |
| Other districts (neighborhood commercial, quasi-industrial, commercial, industrial, exclusive industrial and so on) | 6/10 | 4/10 or 8/10 in areas designated by the Specified Administrative Agency |
- When there are two or more front roads, use the widest (Art. 52(2)).
- If the site abuts a front road 6 m or more but under 12 m wide, at a point within 70 m of a specified road of 15 m or more to which it connects, add Wa = (12 − Wr) × (70 − L) ÷ 70 to the road width (Wr: front road width; L: distance from the specified road to the part where the site abuts. Art. 52(9); Order Art. 135-18).
- When a site straddles several districts, take each district's limit (the designated ratio combined with the front-road limit) and multiply it by that part's share of the site area, then add them up (Art. 52(7)).
Parts excluded from total floor area
| Part | What is excluded | Basis |
|---|---|---|
| Garages and other parking facilities | Up to 1/5 of the total floor area of all floors | Order Art. 2(1)(iv), (3) |
| Disaster-prevention storerooms; battery rooms | Up to 1/50 each | Order Art. 2(3) |
| Emergency generator rooms; water tank rooms; parcel delivery box areas | Up to 1/100 each | Order Art. 2(3) |
| Basement of a residence or care home whose ceiling is within 1 m above ground level | The floor area of that part, but only up to 1/3 of the total residential floor area | Act Art. 52(3) |
| Shared corridors and stairs of an apartment building or care home; elevator shafts | All of it, with no upper limit | Act Art. 52(6)(i), (ii) |
Some floor area ratio relaxations require the Specified Administrative Agency's permission, for example Para. 11 (treating the front road boundary as lying on a designated wall line) and Para. 14 (buildings with an unusually large share of machine rooms, buildings with wide open space around them, and buildings undergoing exterior wall work for energy-saving improvement). By contrast, Para. 12, which treats the road boundary as lying on the wall line for a building whose road-width multiplier is 4/10 and that stays within the wall line, can be used without permission (but the limit of road width multiplied by 6/10 still applies).
Worked examples (our own illustrations)
- Example 1 (floor area ratio): Category I residential district, site 150 sq m, designated coverage 6/10, designated floor area ratio 20/10, front road 4 m wide. The road limit is 4 × 4/10 = 16/10 (160%), smaller than the designated ratio, so the limit is 160% and the total floor area is at most 240 sq m. The building area limit is 150 × 6/10 = 90 sq m.
- Example 2 (weighted average): On a 200 sq m site, 120 sq m lies in a district with 6/10 coverage and 80 sq m in a district with 4/10. The limit is (120 × 6/10 + 80 × 4/10) ÷ 200 = 104 ÷ 200 = 52%.
Minimum site area and setback of exterior walls
Site-related rules
| Rule | Content | Article |
|---|---|---|
| Minimum site area | Where the city plan for a use district sets one, the site must be at least that large. The minimum may not exceed 200 sq m. Land already used as a building site when the minimum was set or changed is not caught if used whole as one site | Art. 53-2 |
| Setback of exterior walls | In exclusive low-rise residential districts and the agricultural residential district, where the city plan sets a limit, the distance from the exterior wall (or columns) to the site boundary must be at least that limit. The limit is 1.5 m or 1 m | Art. 54 |
Common traps
- Stacking coverage relaxations repeatedly. The Art. 53(3) additions are 10 points for a corner lot and 10 for fire protection, 20 points at most.
- Assuming a fire-resistant building in a fire prevention district always gets 10 points. Where the designated ratio is 80%, the limit simply does not apply.
- Judging by the designated floor area ratio alone when the front road is under 12 m. Compare it with the road width times 4/10 or 6/10, and use the smaller.
- Using the narrower road, or an average, when there are two front roads. Use the widest.
- Counting the setback strip in the site area. A part treated as a road under Art. 42(2) is not counted in the site area.
Frequently asked questions
What is the difference between building coverage and floor area ratio?
Building coverage is the building area (the area seen from directly above) divided by the site area. Floor area ratio is the total floor area (the sum of all floors) divided by the site area. A building must satisfy both limits: coverage limits how much of the site is covered, and floor area ratio limits how much floor area can be built.
How much extra coverage does a corner lot get?
A site at a street corner, or a similar site designated by the Specified Administrative Agency, gets 10 percentage points added to the coverage limit (Building Standards Act Art. 53(3)(ii)). Fire-resistant buildings and similar in fire prevention and quasi-fire prevention districts also get 10 points, and a site meeting both gets 20.
What happens to building coverage for a fire-resistant building in a fire prevention district?
Outside districts whose designated ratio is 80%, 10 points are added. In a fire prevention district within a district whose designated ratio is 80% (for example, a commercial district), the coverage limit does not apply at all to a fire-resistant building and similar (Art. 53(6)(i)).
How does a narrow front road affect the floor area ratio?
When the front road is under 12 m wide, the road width in meters multiplied by 4/10 (generally in residential districts) or 6/10 (generally in other districts) is also a limit. The smaller of that and the designated ratio is the real limit (Art. 52(1), (2)). With two or more front roads, use the widest.
What are the ratios when a site straddles two use districts?
Each district's limit is multiplied by the share of the site in that district and the results are added (coverage: Art. 53(2); floor area ratio: Art. 52(7)). It is a weighted average by area, not the stricter limit or a simple average.
In the same land-use restrictions section, also study when a development permit is needed (City Planning Act, Art. 29) and the differences between Articles 3, 4 and 5 of the Agricultural Land Act. Look up terms in the glossary.
Practice coverage and floor area ratio questions on real exams
Use past exam questions to practice the calculation steps and the relaxation checks, then check your score by area.
Sources
- Building Standards Act (e-Gov Law Search) – Arts. 42, 52, 53, 53-2, 54
- Building Standards Act Enforcement Order (e-Gov Law Search) – Arts. 2 and 135-18
- Ministry of Land, Infrastructure, Transport and Tourism: Building Standards Act – Guide to the Building Standards Act system
- RETIO: Real Estate Transaction Promotion Center, Takken exam information – Questions follow the law in force on April 1 of the exam year